Maintenance Vector Control Chassis Type Frequency Converter
476 869 4070 76 J AB-74 Siemens AG
12-12 Operating Instructions SIMOVERT MASTERDRIVES
12.19 Replacing the thyristor modules (V1 to V3, type K)
Replacement as in the case of the TDB, with the following additions:
Disconnect the supply cables C+ D
of the option terminals
Disconnect the connection of the C and D bars between the rectifier
and the inverter.
Disconnect the connections U, V, W of the modules.
Disconnect the connections between modules and C(+) bar.
Remove the connecting bar C(+).
Disconnect the connections between modules and D(
) bar.
Remove the connecting bar D(
).
Undo the module fixing screws (M6, Torx).
Remove the module (weight approx. 500 g).
Clean the contact surface.
Coat the new modules thinly and evenly with a thermo-lubricant and
mount them.
Tightening torque of the fixing screws: 6 Nm ± 15 %.
Further installation is performed in the reverse sequence.
Tightening torque of the electrical connections (C and D): 12 Nm (+
5 %,
10 %).
Fig. 12-6 TDB board, pre-charging resistors and thyristor modules V1, V2, V3